10kv Jszy19-10r with Fuse Voltage Transformer

Product Details
Application: Electronic, Instrument
Type: Current Transformer
Phase: Single
Still deciding? Get samples of US$ 70/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • 10kv Jszy19-10r with Fuse Voltage Transformer
  • 10kv Jszy19-10r with Fuse Voltage Transformer
  • 10kv Jszy19-10r with Fuse Voltage Transformer
  • 10kv Jszy19-10r with Fuse Voltage Transformer
  • 10kv Jszy19-10r with Fuse Voltage Transformer
  • 10kv Jszy19-10r with Fuse Voltage Transformer
Find Similar Products

Basic Info.

Model NO.
JSZY19-10R/10kv
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Open-Closs Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Wooden
Specification
ISO9001, GB/T20840, IEEE, IEC
Trademark
DAHU
Origin
China
HS Code
850431
Production Capacity
10000PCS/Mouth

Product Description

10kv Jszy19-10r with Fuse Voltage Transformer
DAHU electrical specializes in the production of 0.5-40.5kv transformers. It has cooperated with many national power bureaus for 10 years and exported to foreign markets. If
there is any quality problem within the warranty period, it can be replaced free of charge.
10kv Jszy19-10r with Fuse Voltage TransformerProduct Overview:
The JDZ-3/6/10Q series voltage transformers are suitable for power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 3kV to 10kV. They are mainly used for energy metering, voltage monitoring, and relay protection
.10kv Jszy19-10r with Fuse Voltage Transformer
Technical parameters:
Rated primary voltage: 10kV.
Rated secondary voltage: 100V.
Accuracy levels include 0.2 and 0.5, with rated outputs ranging from 15VA to 30VA and limit outputs ranging from 200VA to 400VA. The rated insulation levels are 7.2/32/60kV and 12/42/75kV
.10kv Jszy19-10r with Fuse Voltage Transformer
Normal usage conditions:
Installation location: Indoor.
Environmental temperature: maximum+40 ºC; Minimum -5 ºC.
Altitude: not exceeding 1000m.
Atmospheric conditions: There is no severe pollution in the atmosphere
.10kv Jszy19-10r with Fuse Voltage Transformer
Structure and characteristics:
This type of transformer is a semi cast iron core with an outer core. The primary winding is led out at both ends and equipped with a terminal block, which can be used to connect high-voltage wires
.10kv Jszy19-10r with Fuse Voltage Transformer
The winding of the transformer is an epoxy resin fully vacuum cast fully insulated structure, and the iron core is made of high-quality silicon steel sheets stacked together. The product has a small volume and light weight, and installation only occupies limited space
.10kv Jszy19-10r with Fuse Voltage Transformer
Appearance and installation dimensions:
Specific exterior drawings and installation dimensions can refer to the information provided by the manufacturer or product manual
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer
10kv Jszy19-10r with Fuse Voltage Transformer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier