Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument

Product Details
Application: Electronic, Instrument
Type: Combined Transformer
Phase: Three
Still deciding? Get samples of US$ 900/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
  • Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Find Similar Products

Basic Info.

Model NO.
PV/VT
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Wooden
Specification
ISO9001, GB/T20840, IEEE, IEC
Trademark
DAHU
Origin
China
HS Code
850431
Production Capacity
10000PCS/Mouth

Product Description

DAHU electrical specializes in the production of 0.5-40.5kv transformers. It has cooperated with many national power bureaus for 10 years and exported to foreign markets. If

there is any quality problem within the warranty period, it can be replaced free of charge.Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring InstrumentAccuracy Ratings:

According to the IEEE C57.13 standard, the accuracy ratings for PTs and VTs require a constant allowable range of error over the range of 90% to 110% of rated voltage
. The accuracy class defines the maximum ratio deviation over the specified load range. A PT or VT is considered to have an accuracy class of 0.3 if the maximum ratio error is ±0.3% over the standard load range
.Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
JDZ10-10 type voltage transformer:

This is a voltage transformer for indoor use with an accuracy class of 0.5 for 10kV systems. Its ratio is 11000/110V, rated frequency is 50Hz and rated capacity is 50VA
The rated capacity is 50VA.
GFJDZ1053-10 high accuracy indoor voltage transformer:

This product is used for metering and relay protection of 12kV and below circuits, characterized by high accuracy
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument.
Indoor resin insulated PT/VT:

Medium voltage indoor PT/VTs are cast in epoxy resin and designed for high accuracy medium voltage measurements up to 36kV.
.
Application of Accuracy Class:

For PT, if the accuracy class is 0.3WXMYZ, it will maintain 0.3 accuracy class from 0VA to 200VA (Z load).The accuracy of PT varies linearly with load. At the factory, accuracy is recorded at zero and full load, and this data is available from the manufacturer on request
.Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Selection of Accuracy Rating:

Modern digital meters and wattmeters have very low loads and the accuracy of the VT/PT can be improved by selecting a VT with a lower full load. For example, if 0.3WXM (35VA) is used instead of 0.3WXMYZ (200VA), the actual load of 15VA will be in the middle of the accuracy graph, with a ratio correction factor (RCF) close to 1 and a phase angle error close to zero
.
This information provides an overview of the accuracy classes and associated technical parameters of PT/VTs used in indoor voltage measurement instruments. Accuracy rating is an important consideration when selecting and applying voltage transformers, and it directly affects the accuracy and reliability of voltage measurements.

Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
Potential Transformer (PT) /Voltage Transformer (VT) Accuracy Class Indoor Voltage Measuring Instrument
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier