11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer

Product Details
Application: Electronic, Instrument
Type: Current Transformer
Phase: Single
Still deciding? Get samples of US$ 80/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
  • 11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer
Find Similar Products

Basic Info.

Model NO.
LZZBJ9-10
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Wooden
Specification
ISO9001, GB/T20840, IEEE, IEC
Trademark
DAHU
Origin
China
HS Code
8504311000
Production Capacity
10000PCS/Mouth

Product Description

This type of current transformer adopts epoxy-resin vacuum casting and fully enclosed post structure, is applicable for power systems of rated frequency 50Hz or 60Hz rated voltage up to and including 10kV, used for electric energy metering, current measurement, and relay protection, it can be an arbitrary combination of classes 0.2S, 0.2, 0.5 and 10P.
It complies with the standards GB20840.1-2010 Instrument transformers-Part 1: General requirements, GB 20840.2-2014 Instrument transformers- Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers.



NORMAL ENVIRONMENTAL USAGE
  1. Altitude: Should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air Relative Humidity: Less than or equal to 85%
  4. Air relative site: Indoor.

TECHNICAL PARAMETERS
  1. Insulation level:12/42/75kV
  2. Power factor:cosΦ=0.8(lag)
  3. Rated secondary current: 5A or 1A
  4. Rated frequency: 50Hz or 60Hz
  5. Weight: 21kg

TRANSFORMER RATIO
 
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal
current(kA/s)
Rated insulation level(kA)
5 0.2S
0.2S/0.5
0.2S/0.5/10P10
0.2S/10P10
10
10/10
10/10/15
10/15
0.36 0.9
10 0.72 1.8
15 1.08 2.7
20 1.44 3.6
25 1.8 4.5
30 2.16 5.4
40 2.88 6.3
50 3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 72
600 43.2 108
800 57.6 120
1000-1500 172 144
11kv / 24kv, 35kv Indoor Single-Phase Epoxy Resin Casting Type Current Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier