Residual Winding 35kv Full Operation Mode Voltage Transformer

Product Details
Application: Instrument
Type: Voltage Transformer
Phase: Single
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
  • Residual Winding 35kv Full Operation Mode Voltage Transformer
Find Similar Products

Basic Info.

Model NO.
JDZXW-35 single phase
Operation Condition
Indoor
Usage
Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rated Current
630A
Rated Frequency
50Hz
Rated Voltage
12kv
Transport Package
Wood/Boxes
Trademark
DAHU
Origin
Made in China
HS Code
8504311000
Production Capacity
10000PCS/Per Month

Product Description


Outdoor Potential Transformer (PT)
Definition and Role: Voltage transformer (PT) is mainly used to convert high voltage into low voltage (usually 100V) suitable for instruments or relays, for measuring line voltage, power and electrical energy, or for protecting valuable equipment in the line in case of line failure.
Residual Winding 35kv Full Operation Mode Voltage Transformer
Structure: PT consists of primary winding, secondary winding, iron core terminal and insulation support.
Working Principle: The working principle of PT is similar to that of ordinary transformer with no-load condition, which realizes voltage transformation by changing the ratio of winding turns.
Residual Winding 35kv Full Operation Mode Voltage Transformer
Technical parameters: in the 110kV and above voltage level system, PT usually has two secondary windings, rated phase main secondary winding voltage is 100/31/2V.

Step-down transformer
Definition and function: Step-down transformers are used to reduce high voltage to a voltage level suitable for the safe use of the consumer, e.g. to reduce a voltage of more than 100,000V to a three-phase, four-wire system of 380V.
Residual Winding 35kv Full Operation Mode Voltage Transformer
Technical parameters: The technical parameters of step-down transformer include rated capacity, rated voltage, no-load loss, no-load current, short-circuit loss and so on. For example, the no-load loss of S9-M-800/6 step-down transformer is 1400W, load loss is 7500W, no-load current is 0.8% and impedance voltage is 4%.
Residual Winding 35kv Full Operation Mode Voltage Transformer
PT and VT (voltage transformer)
PT (Voltage Transformer): Used to convert high voltage to low voltage for measurement and protection systems.
Residual Winding 35kv Full Operation Mode Voltage Transformer
VT (Voltage Transformer): Similar in function to the PT, also used for voltage conversion, but specific models and parameters may differ.

The above information provides the basic concepts and some technical parameters of outdoor potential transformers (PTs), step-down transformers, and PTs and VTs. These devices play an important role in the power system to ensure effective voltage transformation and stable operation of the power system.


Residual Winding 35kv Full Operation Mode Voltage Transformer
General

This type of voltage transformer adopts epoxy-resin vacuum casting and a fully closed single-phase structure for indoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and voltage measurement.
It complies with the standards GB 20840.1-2010 Instrument transformers-Part1:General requirements, GB 20840.3-2013 Instrument transformers-Part3:Additional requirements for inductive voltage transformers, and JJG314-2010 Instrument Voltage Transformers.



Use environment 
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative site: indoor.


Technical parameter
  1. Insulation level:12/42/75kV
  2. Power factor:cosφ=0.8(lag)
  3. Rated secondary current: 5A or 1A
  4. Rated frequency:50Hz or 60Hz
  5. Weight: 21.5kg


Technical ratio
Rated voltage ratio(kV) Rated secondary output(VA) Max.output(VA) Rated insulation level(kV) Notes
02 0.5 1 level 2 level
3000/100 15 30 60 150 200 3.6/25/40 Same as "RZL"
6000/100 7.2/32/60
10000/100 12/42/75