• Low Current Measure Zero Phase Current Transformer
  • Low Current Measure Zero Phase Current Transformer
  • Low Current Measure Zero Phase Current Transformer
  • Low Current Measure Zero Phase Current Transformer
  • Low Current Measure Zero Phase Current Transformer
  • Low Current Measure Zero Phase Current Transformer

Low Current Measure Zero Phase Current Transformer

Application: Electronic, Instrument, Position Sensor, Audio
Type: Current Transformer
Phase: Three
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Samples:
US$ 200/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Zhejiang, China
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (25)

Basic Info.

Model NO.
LSY3-10/107
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
OEM
Offered
Frequency
50Hz/60Hz
MOQ
1PCS
Certificate
ISO CCC IEC CE
Rated Current Ratio (a)
75/1,100/1,150/1,200/1,300/1,400/1,500/1,600/1
Rated Secondary Current
5A or 1A
Rated Voltage
0.5kv
Transport Package
Wooden
Specification
Standard or customization
Trademark
DAHU
Origin
China
HS Code
8504311000
Production Capacity
10000PCS/Mouth

Product Description


Low Current Measure Zero Phase Current Transformer
Low Current Measure Zero Phase Current TransformerLow Current Measure Zero Phase Current Transformer

Low Current Measure Zero Phase Current TransformerLow Current Measure Zero Phase Current Transformer
General

This type of transformer adopts an integral casting structure, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 0.66kV, used for current measurement, electric energy metering, relay protection, etc.
It complies with the standard Q/GDW1572-2014 Technical specification of a low-voltage current transformer for metering.


Use environment 
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative humidity:≤85%
  4. Air relative site: indoor.

Technical parameter
  1. Rated secondary current: 5A or 1A
  2. Power factor: cosφ=0.8(lag)
  3. Rated frequency: 50Hz or 60Hz
  4. Rated primary current, rated output, and accurate level see table 1
  5. Insulating property: primary winding to secondary winding and ground, and secondary winding to the ground can bear the power frequency withstand voltage 3kV for 1min.
Type Rated Current ratio(A) Mongline rated secondary output(VA) Twin coil rated secondary output(VA)
0.2S 0.2 0.5 10P10 0.5 10P10
LSY3-10/107 75/5 / / 1 / 1 /
100/5 / / 2.5 / 1 /
150/5 / / 2.5 2.5 1.5 /
200/5 / 2.5 2.5 5 2.5 5
300/5 2.5 2.5 5 5 2.5 5
400/5 5 5 5 7.5 5 7.5
500/5 5 5 10 10 5 10
600/5 5 10 10 10 5 10
800/5 10 10 10 10 5 10

Overall dimension drawing
Low Current Measure Zero Phase Current Transformer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
50
Year of Establishment
2006-03-16