High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10

Product Details
Application: Instrument
Type: Voltage Transformer
Phase: Single
Manufacturer/Factory & Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (26)
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
  • High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10

Basic Info.

Model NO.
LXK-80
Operation Condition
Indoor
Usage
Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Trade Mark
Dahu
Transport Package
Wood/Boxes
Trademark
DAHU
Origin
Made in China
HS Code
8504311000
Production Capacity
10000PCS/Per Month

Product Description

High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10LXK-80 High-voltage zero sequence transformer indoor casting opening and closing through-type core protection device
Product Overview:

LXK-80 series zero sequence current transformer is suitable for indoor, rated frequency 50Hz or 60Hz, rated voltage 10KV below the power system in three-phase AC generator, motor zero sequence current protection.
The product is unsaturated epoxy resin casting open and close structure, convenient for product installation; magnetic conductivity materials used by the annealed toroidal iron core, to ensure that in the primary zero sequence current reaches the set current, the secondary accurate output current for relay action to achieve the purpose of protection.
Technical parameters:

Bore diameter of 80mm, suitable for cable through-center structure, only the insulation of the secondary coil is considered, the secondary coil to ground frequency withstand voltage 3kV
The secondary coil has a working frequency withstand voltage of 3kV to ground.
The installation place is indoor, the ambient temperature is maximum +40ºC, minimum -5ºC, the altitude does not exceed 1000m, no serious dirt in the atmosphere.
.
Structural characteristics:

Adopting "C" type iron core, the secondary coil is wound in two parts on the "C" type iron core and molded by epoxy resin casting. There are clamps at the bottom of the product for installation and fixing.
The bottom of the product has a clip for installation and fixing.
LSY-10 transformer protection device
Product description:

LSY-10 three-phase integrated current transformer is suitable for installation on the three-phase casing of ring network switchgear and main column switch, used for the measurement and protection of three-phase current transformer and zero-sequence current, and can also be used for the measurement and protection of zero-sequence current of multiple cable circuits.
It can also be used for zero sequence current measurement and protection of multiple cable circuits.
The core and secondary winding of this series of zero sequence current transformers are vacuum-wound with high quality epoxy resin in a flame-retardant plastic shell, which is moisture-proof, stable in performance and maintenance-free.
The core and secondary winding are made of high quality epoxy resin vacuum-wound in a flame retardant plastic case.
Technical parameters:

Product performance in line with standards: GB/T20840.1, 2 and IEC61869-1,2, rated secondary current: 5A or 1A, rated frequency 50Hz or 60Hz, ambient temperature: -35 ºC ~ +55 ºC, frequency withstand voltage: 3kV, 1min; altitude: ≤1000 meters.
Altitude: ≤1000 meters.

High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
High-Voltage Zero-Sequence Transformer Indoor Pouring Open-Close Through-Core Protection Lsy-10
Our factory are supply Voltage transformer,current transformer with high quality at competitive price. Should you have any question with our products, Please share with us together.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier